• Four discreet chambers:  one  50" x 14" x 6"  long gun chamber,  two 12" x 18" x 18" cyanoacrylate chambers and one  24" x 18" x 18" cyanoacrylate chamber.

  • Each chamber has internal quartz lighting.

  • The glass in chamber doors are tempered glass.  Doors will seal to prevent CA vapors from escaping.

  • Each chamber has its own switch controlled heated CA fuming system with enhanced 2 ½" diameter CA heater surface.

  • Coaxial dispensing of water and CA in each chamber allows the vapors to mix in free air.

  • Each chamber has provision for external exhaust through a series of ports.  The standard primary exhaust port will be 4" in diameter on the left side.  Alternate location may be requested upon ordering.  A 24" clearance is necessary on each side of the equipment to operate the individual vent assemblies for the fuming compartments.

  • The overall cabinet is treated aluminum with a powder coated beige finish.

  • Power requirements: 115V, 20 amps, U ground GFI receptacle.

  • You will require an extractor fan supplied by others with outside exhaust @ 640 cubic feet per minute.