Filnor
has been one of Americas leading specialists in the design,
manufacture and supply of high quality resistor products for over 36
years and is ISO9001 certified. Their products encompass a variety of areas including Load Banks, Neutral Grounding systems, Disconnect Switches,
Motion & Crane controls, Harmonic Filters & Damping
Resistors, and Dynamic Braking
resistors.
|
|
|
Filnor
specializes in Neutral Grounding Resistors. Neutral
Grounding Resistors are used to protect power transformers, power
generators and other associated equipment in your power systems against
50/60 Hz faults (short circuit) and transient phenomena (lightning). All
Filnor Neutral Grounding Resistors are designed, rated, manufactured
and tested in strict compliance with IEEE-32. They have been at the forefront
of innovative resistor design and have built
a solid reputation as a high quality manufacturer of durable,
competitively priced resistors for the power generation industry.
In
addition to their standard line resistors, they have a large
engineering department of experienced resistor designers, which can
provide custom engineered units to meet your specific requirements.
|
|
|
|
|
|
RESISTOR PRODUCTS
|
|
|

|
|

|
|
|
Load Bank
|
Neutral Grounding
Resistor
|
Special Neutral
Grounding
|
|
|
|
|
|
|
DC Crane
Resistors
|
Harmonic Filter
|
Harmonic Resistor
|
|
|
Filnor offers a full
range of quality products, designed to meet virtually all your power
resistor needs. Their experience and expertise allows them to
meet the differing needs of the international market place with custom
made resistors at competitive prices, and quick turnaround times. The
maximum power ratings specified are for resistors mounted in an open
air atmosphere. If units are to be mounted closer together or in a
restricted ventilation condition, the maximum power rating should be
derated as follows. Resistors in a well ventilated enclosure should be
rated at approximately 82% and in and unventilated enclosure at
approximately 67% of their maximum power rating.
Bolted
Pressure Contact, Medium Voltage, High Current, & Knife Disconnect Switches
are designed for ease of
operation, low maintenance, dependability, and safety. They
manufacturer economical switches for many industries including utility,
telecommunications, marine, mining, chemical, transit, and
construction. A large variety
of manual, pneumatic, and electrical Switches are available and
produced in house.
Typical Applications: Generator, Battery,
or Rectifier Disconnects, Transfer Switches, UPS Systems, Crane
Rail Isolation, Transit Third Rail Disconnects, and other applications.
Switch Capabilities:
Bolted
Pressure Contact Switches, Grounding Switches, Hook Stick Switches,
Knife Switches, Special Design Switches, Transfer Switches, High
Current Switches, Test
Switches, etc.
SWITCHES
|
|
|
|
|
|
|
Generator or
Battery Disconnect
|
Grounding Switch
|
Master Control
Switch
|
|
|
|
|
|
|
Disconnect Switch
4160VAC
|
Knife Switch
|
Pneumatic
Disconnect Switch
|
|
|
|
|
|
|
High Current
Switch
|
Knife Switch
|
Special
Disconnect Switch
|
|
|
CONTROL
PANEL PRODUCTS ( AC or DC )
Filnor designs and manufactures AC/DC electric motor controls and related accessories including pilot control devices, festoon systems and magnet controls.
Class 3010 and Class 3011 AC Magnetic Heavy Duty Crane Control for Hoist, Trolley and Bridge Service. NEMA Class I Service, CMAA Classification D, E, & F Service.
Pendant Station & Two motion (Joy Stick) Master Switches can be furnished with or without spring return, for AC or DC service, in floor mounting stand or for mounting in
console.
|
|
|
|
|
|
|
Manual Bus
Disconnect
|
DC Controls
|
Hand Held
Controller
|
|
|
|
|
|
|
|
|
Fuses, Fuse Blocks &
Clips
|
|
|
|
|
|
|
STANDARD
RESISTORS
|
|

|
 |
 |
|
|
|
|
Grid Resistors: Reliable stainless steel resistor elements and
terminals: All units are triple insulated for 1000Volts AC or
DC. Standard grid resistors in stock to reduce costly
downtime. Stable resistance over wide temperature ranges.
High wattage saves space, weight and cost. Standard 26.5"
dimensions for quick replacement of other brands. Custom grids
are available. |
Helicoil Wirewound Resistor: Applications including: Resistance
Neutral Grounding, Braking for AC/DC drives, Starting and Speed
Regulation Uses, Ballast Resistors and Heaters. |
Smooth
Wirewound Resistor:
Applications
including: Resistance Neutral Grounding, Braking for AC/DC drives,
Starting and Speed Regulation Uses, Ballast Resistors and Heaters.
|
|
LOAD
BANKS AVAILABLE |
|
|
Load Banks provide
electrical loads for testing purposes and reduce undesirable conditions
in back-up generating systems. With multiple element types at our
disposal, a reliable and efficient product tailored to your needs is
always available. All of the resistors are made in house so they are
not captive to any supplier’s delivery schedule. The unique
ability to design and supply to your specifications is our advantage; a
quality product delivered in a timely manner at a reasonable price is
yours.
Radiator & Duct
Mounted Load Banks: Using the engine’s radiator air
flow for cooling the resistor elements, these load banks are suitable
for use on stationary and portable generator sets. Dimensions are
matched to your core making this a cost effective solution for periodic
testing and minimizing “wet·
stacking”. Sizes range from 10 to 1500 kW at 208 to 600 VAC. Steps
can be configured as required.
Stationary Load Banks: Whether indoor or outdoor,
purely resistive or resistive/reactive, a solution is readily
available. Each model can be modified for a particular application,
such as adding iron-core reactors, control power transformers, remote
mountable controls, digital metering, lockable access doors, and a host
of other possibilities. Alternatively,
these banks may be trailer mounted for increased flexibility. Available in low and medium
voltages, models range from 15 to 4000 kW, with reactive loading
possible from 15 to 3000 kVAR.
Portable Load Banks: A complete line of portable load banks, ready for shipment
when you need them. With their engineering experience and manufacturing
capabilities combined with your application, we can have a custom
designed product that will meet your particular needs. Hand carried, on casters or lifting
channels, we have a solution for your requirement. AC load banks are
available from 120 to 600 VAC, and capacities ranging from 10 to 800 kW
(resolution as required for your particular application). DC load banks
are rated up to 1000 amps with voltages spanning 24 to 270 VOC. |
|
|
|
LOAD
BANK models
are available in
many configurations...
|
STATIONARY Models:
|
Indoor Ductable or Weatherproof,
and Radiator Mounted
|
|
PORTABLE Models:
|
Containerized Caster, Fork-
Liftable, or Trailer mounted
|
|
SPECIFICATIONS:
|
National Electric Code, NEMA,
NFPA 70, 99, 110
|
|
VOLTAGES:
|
120VAC single phase to 25KVAC 3
phase; (DC is available)
|
|
COOLING:
|
Natural-Cooled or Forced Air
|
|
SIZES:
|
20KW to 2MW (Can gang
together units to any size)
|
|
|
|
|
|
·
Load Bank General Description:
(All features are quoted upon request, see
submittal for details and clarification).
Filnor load banks will be
resistive (or resistive/reactive) per the customer’s specification
for use as an electrical load for diesel generators or equivalent. The
load bank will be one of several available types: portable, stationary,
trailer-mounted or radiator/duct mounted. While standard designs exist,
multiple options are possible for the enclosure style, controls and
accessories.
Ratings:
As a manufacturer of power resistors,
they are able to offer an infinite range of ratings. Selection
criteria is based on AC or DC use, single or three phase as well as the
voltage and current combination.
Resistors: Filnor resistors are chosen per the particular rating and application of the
load bank they are to be used in.
They can be Grid, Helicoil Wirewound, or Smooth
Wirewound (as selected for the power steps required). Wound elements are made of a stainless steel alloy,
wound on a ceramic core, suspended on stainless steel rods. The rods are subsequently mounted within a supportive
channel structure. The
Grid elements are a stamped and welded
or continuous resistor weave, made of a stainless steel alloy and
developed for heavy-duty applications.
The resistor is anchored by high temperature insulators and then
mounted in a channel structure.
All resistors are rated for continuous duty and do not
require a cool-down period. Unless
otherwise specified, the resistors are connected in a delta scheme.
Cooling:
The standard cooling arrangement for
non-radiator mount units is for one or multiple fans per section of
resistor assemblies. Standard fans are rated 208V, 3 phase, 60Hz for
208VAC load banks, 240V, 3 phase, 60 Hz for 240VAC load banks, or 480V,
3 phase, 60 Hz for either 480VAC or 240/480VAC load banks. Power to the fan is customer
supplied unless otherwise specified.
Please
refer to submittal drawings for clarification. Radiator/duct mounted applications
are designed to be cooled by an engine mounted generator fan.
(All features are quoted upon request, see
submittal for details and clarification).
Control
equipment: As a standard, load banks are
supplied with the controls integral to the resistor assembly enclosure. Other options exist including a
remote cabinet for the main controls (cabling done by the customer
between the load bank and remote cabinet). Control power (120 V) is
customer supplied unless a control power transformer is included in the
offer. Controls typically consist of a Main Power On/Off switch, Blower
On/Off switch with indicator (where appropriate), Voltage selector
switch (for dual voltage models) Load Steps On/Off switch and
individual step controls with indicating lamps. Individual step controls are tied to contactors rated in
accordance with the step’s particular amperage. Optional equipment available include: Analog or Digital
metering, automatic load leveling, and automatic load dump.
Enclosures: The load bank will consist of an
enclosure with resistor assemblies, control circuitry, and ventilation
equipment (where applicable). The enclosure will be of type NEMA 1
(unless otherwise specified), Enclosure finishes and materials are also
application specific. Options include louvers (NEMA 3R, NEMA 12), protective screening, lifting
handles, lugs and/or channels, and casters. Hot rolled steel with
ASA70 gray epoxy powder coat is the Filnor standard with
options including mill galvanized, aluminum and stainless steel, or
special color. Ventilation will be either horizontal or vertical based
on the application and the customer’s specification. Depending on the application,
the load banks are natural convection cooled or forced air-cooled. A
host of options are available including high temperature cut-out
switches, alarm relaying, RTD’s, and door/panel mounted
instrumentation. Radiator/duct mounted applications
are sized to meet the customer’s requirement. The frame may be lifted with
slings, or optionally with lifting lugs if specified. A removable access plate and
conduit entries are provided for the customer’s connections.
Protection
equipment: Typical protection equipment
includes a differential pressure switch to provide an airflow alarm,
(optional on radiator mount units). Automatic
Load Dump Feature: This is typically coupled to an indicating lamp and general-purpose
relay to open load step contactors in the event of a failure. A temperature-sensing switch
operates in the same fashion. Optional
equipment includes fusing for the fan, incoming connection and
individual load steps.
Documentation: Filnor will provide a general outline
drawing and an electrical schematic drawing to the customer for
approval within two weeks of receipt of a technically clear and
official order. These drawings must be returned
approved prior to manufacturing. One
operation and maintenance manual will be shipped with each load bank
and additional copies are available at a nominal adder. (All features are quoted upon request, see
submittal for details and clarification).
|
|
|
|
|
|
|
High Current
Load Bank for NYC Transit System
|
Load
Bank Assembly for Crane
|
|
|
|
|
|
|
|
|
|
|
|
|
|
·
Neutral Grounding: Function:
Neutral Grounding Resistors are used to protect power transformers,
power generators and other associated equipment in your power systems
against 50/60 Hz faults (short circuit) and transient phenomena
(lightning). Whether protecting your equipment or lowering system
fault levels, Filnor neutral grounding resistors come in a range of
configurations to meet your needs. Coupled with your generators
and transformers, neutral grounding resistors limit ground faults and
protect against potentially damaging over-voltages. Designed for
your particular application, we can meet your needs for time rating (5
second to continuous), enclosure style (painted, aluminum, stainless
steel, hot-dipped galvanized, etc.) and other options (instrument
transformers, elevating stands, bushings, switchgear, controls,
etc.). When shutting down your production is not a cost-effective
solution, High-resistance grounding systems allow money to be made
while allowing faults are being located and repaired. A range of
options is offered to provide the protection and piece of mind you need to keep producing. (All features are quoted upon request, see
submittal for details and clarification).
SPECIFICATIONS
There are three parameters needed to specify the neutral grounding
resistor.
1. Rated voltage line to neutral or system voltage
2. Rated fault current
3. Rated “time on” of the line to neutral voltage not exceeding the
allowable temperature rise.
RANGE
• Rated current: from 1 amp to 5000 A
• Rated voltage: from 0.38 to 34.5kV
• Rated time: 1 sec to continuous time rating
TESTING AND QUALITY
All Filnor Neutral Grounding Resistors are designed, rated,
manufactured and tested in strict compliance with IEEE-32. Routine
tests performed on each Neutral Grounding Resistor are measurement of
resistance, high voltage power frequency, insulation measurement,
aspect verification, dimensional control. Filnor’s internal quality
system has been developed and certified under ISO 9001 quality system.
CONSTRUCTION
Standard unit includes the stainless steel resistor assembly plus all
the required insulators, internal connections and hardware installed in
a standard safety enclosure. Neutral Grounding Resistor units are
completely assembled, prewired, and tested at our facility. For
shipping all units are crated for added protection and ease of
handling.
ENCLOSURE FEATURES
• Solid overhung top slightly sloped to prevent standing water and
will support heavy ice and snow.
• Forged eyebolts in all four corners for easy hoisting.
• Removable front and rear louvered covers for easy access for
connection and inspection.
• Corrosion resistant nameplate provides complete ratings and
manufacturers information.
• Heavy powder coat ASA 70 Grey finish provides maximum protection.
• Bottom screening prevents the entry of birds and rodents while
providing maximum cooling for the resistors.
ENCLOSURE OPTIONS
• Aluminum, mill galvanized, stainless steel and hot-dipped
galvanized construction. Custom paint finish is available.
• Top or side mounted entrance bushing (s).
• Screened covers for indoor applications.
• Support stands for elevating the enclosure above ground.
OPTIONS
• Current or potential transformers mounted and pre-wired at our
facility
• ON or OFF Load disconnecting switches
• Space heater
• Specially designed units for hazardous or high altitude locations

Other Markets: (All features are quoted upon request, see
submittal for details and clarification).
· Harmonic
Filters and Damping Resistors:
To be used in conjunction with capacitors and inductors,
harmonic filter resistors must dissipate continuous loads and fit
easily in the system. Their range of enclosure designs and resistor
styles allows for compact assemblies and low induction designs to meet
the needs of industrial and utility applications alike. Our engineering
staff understands your requirements and will provide service and
product with unsurpassed expertise.
·
Dynamic Braking Resistors are
used with AC Variable Frequency Drives to produce a braking torque in
the motor during overhauling load conditions. The dynamic braking
resistor is connected across the DC bus and can see voltages as high as
800 volts (DB Resistors are double insulated and rated for 1,000
volts). The resistance value in Ohms determines the amount of braking
torque produced and thus the rate at which the motor will stop. This
value must be within acceptable limits for the particular drive and
application. The resistor wattage is sized to prevent overheating
during normal braking cycles. High duty applications require larger
(higher wattage rated) resistors. DB resistors are often added to
prevent over-voltage trips on the drive when stopping the motor.
· Motion & Crane Controls: Safe
and precise starting and stopping of electric motors isn’t a luxury -
it’s
a necessity. Their resistors for motor control have been tried and
proven to give the long-life and specific ratings needed for your
materials handling systems, cranes and hoists. Filnor resistor
solutions can be found in mining, pulp and paper, metals refining and
ship loading facilities, to name just a few application areas.
·
Festoon Systems:
Festoon Systems provide a simple, inexpensive method of handling cables and hoses. |
|
|
|
|

|
|
|
|
|
|
|
|
|
|
|
|
|
|