Measuring Equipment Solid Measure - Scale
Liquid Measure
Droppers
Calibrating the Droppers
Accessories
Measuring equipment only needs to be as accurate as necessary to maintain consistent results from the process. Chemicals for the coating solutions (sensitizer, metal salts, contrast agents, other) should be measured with an accuracy of 0.01 grams and 0.01 ml. Developers and clearing baths can be measured with an accuracy of 1 gram and 0.5 ounce (15 ml). Liquid film chemistry can be measured with an accuracy of 1 ml.It is recommended to use only glass or plastic for measuring equipment and accessories. Metal should NOT contact any chemical as some metals (especially iron) can adversely hinder the process.
Solid Measure - ScaleScale should be accurate to .01 gram
The Ohaus Cent-o-gram quad balance works fine.Also shown are plastic spoons and funnels and glass or plastic sheet to catch spills.
top of page
Liquid Measure
10 ml medicine syringe (accurate to .1 ml) - 2
1 ml medicine syringe (accurate to .01 ml) - 1
100 ml graduate - (glass, accurate to 1 ml) - 1
50 ml graduate - (glass, accurate to 0.5 ml) - 1
32 oz glass measuring cup (accurate to 0.5 oz) - 2![]()
top of page
Droppers
Droppers (with bottles) (all should be glass and calibrated as below) - 7+top of page
Calibrating the Dropperstop of pageMaterials:
droppers (glass) the small calibrated syringe (1 ml, accurate to .01 ml) masking tape chemical resistant epoxy paint distilled water
Instructions to calibrate:
determine the amount required to be dispensed fill syringe to desired amount with distilled water (distilled is used so as not to contaminate the dropper.) remove bulb from dropper placing finger over narrow end of dropper and holding with large end up, fill with measured syringe contents place masking tape on dropper so that edge is at the level of the water and the tape covers the dropper above the water level. (If a meniscus is seen, measure from the bottom of the meniscus.) release water from dropper mark a line on the dropper at the tape edge using the epoxy paint remove tape and let paint dry
Using:
fill dropper with solution to above paint line then empty some solution so that the top of the solution is at the top of the paint line (If a meniscus is seen, measure from the bottom of the meniscus.) empty entire dropper into destination The delivery might be slightly less due to solution sticking to the dropper surface, but should be very consistent.
Accessories
Spatula or small spoons to handle dry chemicals (glass or plastic) - 3
Stirrer (plastic)
Funnels (plastic, with small end so as to fit on the 2 oz dropper bottles) - 2
plastic sheet - to catch spills when weighing out dry chemicals
appropriate personal safety equipment - glasses, mask, gloves